5.2.1 OKIOFFICE44/OKIFAX 4100 Confirmation Items
The clock frequency and power voltage of the machine are not possible to adjust in the field.
However, their measurement procedures are described here for confirmation of clock frequency and each
voltage.
1) Clock Frequency
Measurement point: R44 board; LC2-3 pin and ground terminal
Specification: 20.000 MHz ± 50 PPM
Note: If the counter does not read with 20.000 MHz, replace with a new crystal oscillator (X1).
2) +5V DC Voltage (SUB)
Measurement point: R44 board; CN7-12 pin and ground terminal
Specification: +5V ± 4% (+4.5V to 5.2V)
3) +5V DC Voltage
Measurement point: R44 board; CN7-1, 2 & 3 pin and ground terminal
Specification: +5V ± 4% (+4.5V to 5.2V)
4) 8V DC Voltage
Measurement point: R44 board; CN7-9 pin and ground terminal
Specification: 15V to 6.5V
5) +30V DC Voltage
Measurement point: R44 board; CN7-8 pin and ground terminal
Specification: +24V to +45V
6) Contact Image Sensor Output (SIG signal)
Measurement point: R44 board; CN5-1 pin and ground terminal
Specification: A waveform sample is shown below.
Test chart: White sheet (A4 size)
2.0Vp-p
5ms